Does Your HVAC Coil Selection Program Leave You With More Questions Than Answers?

At Capital Coil & Air, we have an accurate and user-friendly coil selection program to select and choose coils. Of course, making good selections is based on having years of experience working with coils of all types and sizes, and Coil Selection Programwe at Capital Coil have that necessary expertise.

When designing a coil, the object is to balance cost and performance together, and that is one area in which we can greatly assist. We do not always choose the cheapest coil because the cheapest coil in almost never the best coil. There are always pressure drops, materials of construction, performance requirements and a host of other things that all play into good or bad coil selections. These are even more relevant in the coil replacement market!

The object is not to duplicate a problem with a coil, but to instead solve the problem and make the coil perform better and last longer. This requires problem solving and making selections that are not always “in the box”.

Part of any successful selection process is having a good selection program to help you. But what makes a program good? First and foremost, you must get the correct results, or you have bad information that is also useless. But apart from that, the selection program must be easy to navigate through. There are “red lights” and “stop signs” built into the program to keep you from making bad selections. Our selection program has most, if not all, coil configurations and styles that you’re likely to run across. We are confident that you’ll find the selection program user-friendly, helpful, and one that makes you want to do business with Capital Coil & Air.

You simply have to click here to request the program, and we will send you an email in response with an activation code and a link to download the program. Of course we are always here to assist you in any selections that you make, or to give you some engineering suggestions and recommendations. Thanks for giving us the opportunity to help you!

RELATED POSTS

10 THINGS THAT YOU DON’T KNOW ABOUT CAPITAL COIL & AIR

10 Things You Need to Know to Buy Replacement Coils Effectively

Repair or Replacement Coils?


Stock Hot Water Coil – Quick Buyers Guide

Hot Water Coils

Depending on the specific project, selecting the appropriate Hot Water Coil can go one of two ways:  1) costly and complicated or 2) cheap and rather straight-forward. If you’re a representative or contractor reading this, you understand this fact all too well. And if you’ve dealt with us, you know that we much prefer going the second route rather than the first.  Considering the complexity of other types of coils, hot water coils should be as easy for to purchase and get delivered as they are for the manufacturer to build and keep in stock. So…why is it so hard to get your hot water coils shipped to where you need them when you need them?

Capital Coil & Air decided to create a quick buyers guide to when selecting and purchasing Stock Booster Coil Replacements :

  • First and foremost, you need to determine whether the booster coil needs to be 1 or 2 rows deep. Keep in mind that a 2 row booster coil will always generate substantially more BTU’s than a 1 row booster coil, but will also cause your air pressure drop to rise.
  • Generally speaking, booster coils are primarily installed someplace in the ductwork. If your duct size doesn’t match exactly with what we can build a good rule of thumb is to request your coils be built slightly larger than the ducts where they are going to be installed.
  • Booster coils are offered in sizes anywhere from 6” x 6” to 30” X 72”. Booster coils are 1 or 2 row coils that are available in 60 sizes.  Flanged or Slip & Drive casings are available on every size to meet your needs.
  • While most manufacturers claim they have “booster coils in stock”, and then ship in a week, we actually have (30) sizes in stock ready to ship the next day!

Whether you need (1) hot water coil or (200) hot water coils, Capital Coil & Air has the most competitive pricing in the business with the best lead times. Please see our Booster Coil Product Page. Most companies don’t want to bother with hot water coils.  No one does hot water coils better than Capital Coil & Air!

Related Topics

Stock Hot Water Booster Coils

Booster Coil Basics

Booster Coil FAQ’s


What Does “Splitting” A DX (Evaporator) Coil Mean?

“Splitting” a DX (Evaporator) coil is one of the toughest concepts to understand in the coil business. “Splitting” the coil simply means that (2) compressors can operate off of the same coil. One obvious advantage, or reason that you might “split” a DX coil is that you can shut down (1) of the compressors when the cooling load does not require it. This in turn saves energy, which saves $ when the cooling load is not operating at maximum design conditions. For example, let’s use a coil that is designed to give you (40) tons, but the coil is split so that (2) 20-ton compressors are feeding the same coil. If you only require ½ of the maximum load on any given day, you can shut down (1) compressor completely and operate the other one at 100%. This is a money-saving feature that you need to be aware of if you deal with DX coils on a regular basis. This requires special circuiting arrangements, and this is where the confusion starts with most folks. There are three primary ways to deal with this:

FACE SPLIT

Splitting the coil is nothing more than putting (2) completely separate fin/tube packs (coils) into one common casing. When you hear the term “face-splitting” a coil, you are drawing a horizontal line from left to right across the face of the coil and dividing the coil into a top and bottom half. It is like having two separate coils in one casing in that each half is circuited by itself. You hook up (1) compressor for the top half, and (1) compressor for the bottom.

In practice, this configuration is no longer used with much frequency because this arrangement leads to air being directed across the entire face of the coil. This disadvantage is especially apparent when only one half of the coil is in use because you’ll need a complicated damper/duct system to ensure that air is only directed to that portion of the coil in operation.

Row Split

“Row splitting” a coil is dividing the coil by drawing a line vertically and putting some portion of the total rows in (1) circuit, while putting the remaining rows in the other circuit. With this configuration, the air passes across the entire face of the coil, and will always pass across the rows that are in operation.

Please be aware that this configuration also comes with certain issues in that this kind of split makes it very hard to achieve a true 50/50 split. Let’s use an (8) row coil as an example. You would like to “row split” this coil with (4) rows/circuit, which would appear to be a perfect 50/50 split. The problem here is that the first (4) rows, located closest to the entering air, pick up a much higher portion of the load than the last (4) rows. In actuality, this coil’s split is closer to 66% / 34%, which will not match the 50/50 compressors. Another option is try to split the coil between (3) & (5) rows. While not 50/50 either, this configuration is closer. However, a new challenge arises because you have now created a coil that is very difficult to build and correctly circuit. In short, you need almost perfect conditions along with a degree of luck to achieve a true 50/50 split using this method.

Intertwined Circuiting

The most common to split coils today is to “intertwine” the circuiting. This means that every alternate tube in the coil is included in (1) circuit, while the other tubes are included in the (2nd) circuit. For example, tubes 1, 3,5,7,9, etc. in the first row are combined with tubes 2, 4, 6,8,10, etc. in the second row. The same tubes in succeeding rows form (1) circuit. You are essentially including every alternate tube in the entire coil into (1) circuit, which (1) compressoDX (Evaporator) Coilsr will operate. All of the remaining tubes not included in the first circuit will now encompass the second circuit.

The advantage of this configuration is that the air passes across the entire face of the coil, and, if one of the compressors is on, there are always tubes in operation. Every split is now exactly 50/50 because it cannot be any other way. Most DX coils are now configured in this manner due to these advantages.

 

Capital Coil & Air has years of experience measuring, designing and building almost every OEM DX coil that you’ll come across, so please let us help you on your next project. We want to be your replacement coil experts and look forward to the opportunity.

RELATED POSTS

CHILLED WATER, DX (EXPANSION) COILS & MOISTURE CARRYOVER

Different Types of Steam Coils?

DX & Chilled Water Cabinet Coils

 


Tired Of Wondering If Quick-Ships Will Be Available When You Need Them Most?

With summer seemingly flying by, chances are that you have been getting urgent requests by customers to order replacement coils and have them installed within very tight windows. You’ll run into this with schools for example when, understandably, they’d like to handle everything during the summer break. If that happens, what next? You can call the OEM, but more times than not, they are not flexible or nimble enough to handle your request/emergency within the allotted time-frame. DX Coil

Why is this? Many manufacturers take on a glut of OEM business, or other large projects with small profit margins. In many cases they do this simply to keep the factory running during the slower periods of the year. This has the effect of delaying standard lead times, and in many cases, cancelling quick-ships altogether. It is very hard to do business with companies that make themselves unavailable when you need them the most.

Other cases may simply be logistical. For example, an OEM might be transferring plant locations. They will eventually get back online, but how does that help you in your current “emergency” situation?

Quick-ships are generally based on emergency conditions, and that is precisely the worst time to discover that your regular supplier has suspended their quick-ships. When we call Capital Coil reliable and dependable, one of the main reasons is because of our ability to keep our quick-ship program open 12 months/year. Capital Coil does not try to be all things to all customers, but quick-ships are an integral part of our business. Keeping our quick-ship program available all year is a top priority, and this has allowed us to hit 99.9% of our quick-ship requests over the last (3) years – an unfortunate forklift mistake makes up the other .1%. 5.5 months into 2019, approximately 75% of all orders have been quick-ships, and they have either all been completed on time, or are 100% on schedule.

An RFQ that sits on a desk unanswered is useless to everyone involved. If you need a quote, you’ll have your price and any required submittals that same day. It really is that simple and easy! Working with Capital Coil removes many of the annoying and unannounced shut-downs that come with other manufacturers, so please let us help you when you need it the most!